WARNING!Gas-Fired Infrared Quad Tube HeaterKeep these instructions for future reference.LIOBRHAVS 0911Brant Radiant Heaters, Ltd.AVS SeriesNot for res
AVS Series10WARNING!Improper installation, adjustment, alteration, service or maintenance can cause property damage, serious injury or death. Read and
AVS Series11*Factory recommended mounting heights and approximate coverages are listed as a guideline for designing for total building heat. However,
AVS Series12Heater Packaging3.0 Installation • Heater Packaging Heaters are made up of three pieces shipped in two boxes; the burner control box in t
Vent Cap (WVE-GALV)AVS Series133.0 Installation • Heater AssemblyAssembly prior to hanging: With this method, the use of two saw horses or a raised ta
AVS Series143.0 Installation • Heater Assembly • Preparing Points for HangingDETAIL ‘D’Secure burner reflector end cap (TP-6085A) with (2) 5/16”-18 kep
AVS Series153.0 Installation • Preparing Points for Hanging • Hanging TypesFigure 3.5 • Hanging TypesWood BeamI-BeamI-BeamConcrete BeamSupport Blockin
AVS Series163.0 Installation • Hanging Pre-Assembled Unit1 Raise the assembled unit from assembly station to prepared hanging location. NOTE: This ca
AVS Series173.0 Installation • Hanging Pre-Assembled Unit • Final Check List4.5”83”13.5”12.75”11.5”7” 7” 12.75”Figure 3.7 • Hanging the Heater (Side V
AVS Series183.0 Installation • VentingVentingWARNING!Insufficient ventilation and/or improperly sealed vents may release gas into the building which co
AVS Series193.0 Installation • Venting • Unvented OperationWhen using an unvented configuration (agricultural use only), consider the following: • A
AVS Series2Contents1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AVS Series203.0 Installation • Venting • Sidewall VentingFigure 3.11 • Sidewall Venting Requirements Sidewall VentingGuidelines: Vent Pipe Angle
AVS Series213.0 Installation • Venting • Rooftop Venting*Consult the NFPA ANSI Z223.1 Gas Vent Termination criteria if roof pitch exceeds 9:12.Rooftop
AVS Series223.0 Installation • Venting • Common VentingFigure 3.13 • Common Rooftop Venting - Side ViewCommon Venting • When joining two heaters t
AVS Series233.0 Installation • Combustion Air RequirementsCombustion Air RequirementsCombustion air may be supplied to the heater by indoor or outdoor
AVS Series243.0 Installation • Combustion Air Requirements 4 in. 20 ft. 4 in.(single)/6 in.(dual)
AVS Series253.0 Installation • Gas Supply Natural 3.5 Inches W.C. 5.0 Inches W.C. 14.0 Inches W.C. Liquefied Propane 10.0 Inches W.C. 11.0 Inche
AVS Series263.0 Installation • Gas SupplyCAUTION!When using a Type 1 rubber flexible gas connector, do not attach the connector nuts directly to the ga
AVS Series273.0 Installation • Gas Supply Attach the flexible connector to the adapter and burner control box inlet. Seal the joints. NOTE: Excessiv
AVS Series28The heater must be electrically grounded in accordance with the following codes:United States: Refer to National Electrical Code®, ANSI/
AVS Series293.0 Installation • Electrical Requirements • Field WiringWARNING!Electric ShockField wiring to the tube heater must be connected and groun
1.0 IntroductionAVS Series3OverviewThe intent of this manual is to provide information regarding safety, design guidelines, installation, operation an
AVS Series303.0 Installation • Electrical Requirements • Internal Wiring DiagramsBefore field wiring this appliance - Check existing wiring; replace if
AVS Series313.0 Installation • Electrical Requirements • Internal Wiring DiagramsFigure 3.24 • Internal Block Wiring Diagram
AVS Series324.0 Operation • Operating Instructions • Lighting Procedures • Shutdown Procedures4.0 OperationWARNING!BEFORE OPERATING, smell all around
AVS Series334.0 Operation • Sequence of OperationWARNING!This heater must be installed and serviced by trained gas installation and service personnel
AVS Series34Do both burners light?5.0 MaintenanceTroubleshooting Guide5.0 Maintenance • Troubleshooting GuideTurn up thermostat/controller.Does the fa
AVS Series355.0 Maintenance • Troubleshooting Guide*NOTICEBypassing any switch is intended for testing purposes only. Do not leave switch bypassed du
AVS Series36Troubleshooting ends.5.0 Maintenance • Troubleshooting GuideDo the burners stay on for approx. 15 seconds and then shut off?Continued from
AVS Series375.0 Maintenance • Troubleshooting GuideCheck to make sure gas pressure is within minimum and maximum inputs as indicated on the heater’s r
AVS Series38Chart 5.1 • Parts List5.0 Maintenance • Heater Components and Parts ListPart No. Description Part No. DescriptionTP-13 #8 x 1/2” Self-Dril
AVS Series39Figure 5.2 • Tube & Reflector Components5.0 Maintenance • Heater Components and Parts List Part No. Description Part No. DescriptionTP-
AVS Series40Personal injury or death may result if maintenance is not performed by properly trained gas installer or service personnel. Contact the i
AVS Series41Date Maintenance Performed Replacement Parts RequiredMaintenance Log5.0 Maintenance • Maintenance Log Inspection
AVS Series42Notes
AVS Series435.0 Maintenance • Limited Warranty Terms and ConditionsLimited Warranty Terms and ConditionsOne-Year Limited Warranty. Radiant Tube Heater
Kit Contents Check ListAVS Series Kit Contents5.0 Maintenance • Kit Contents Check ListChart 5.2 • Kit Contents for AVS SeriesAVS SeriesLimited Warran
Right Panel Left PanelNEUTRALEARTHHOT- 120V HEATER INPUT -120VF/N: LLV3EP1F/N: LLTCL013: Clearance to Combustibles and Gas Data LabelCLEARANCE TO COM
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.Young child
Standards, Certifications and Government RegulationsInstallation of this tube heater must conform with all applicable local, state and national specific
WARNING!Placement of explosive objects, flammable objects, liquids and vapors close to the heater may result in explosion, fire, property damage, seriou
Model Number Top Sides Below Back EndAVS-40 [N, P]25.4 91.44 101.6 15.24 30.48AVS-60 [N, P]25.4 91.44 101.6 15.24 30.48AVS-80 [N, P]25.4 91.44 101.6 1